Operating Instructions Chapter 3
ICR880/890
Product description
8011325/XL85/2013-08-20 © SICK AG · Germany · All rights reserved · Subject to change without notice 27
The illumination is controlled by the Camera and can be switched on permanently or for the
duration of the internal reading gate.
If the reading gate does not run to the end due to an error (e.g. when the conveyor system
stops), the illumination automatically switches off once the settable timeout has expired. In
order to prevent epilepsy, the minimum power-on time of the illumination is 3 s.
The illumination mode and the timeout for the ICI890 Illumination can be configured using
the SOPAS-ET Configuration Software:
P
ROJECT TREE, ICR880/890, PARAMETER, READING CONFIGURATION, ILLUMINATION CONTROL, register
tab I
LLUMINATION MODE
Fig. 3-7: ICR880/890 Camera System with deflection mirror for reading from above