EasyManua.ls Logo

SICK LMS511-11100 Lite Outdoor - Page 73

SICK LMS511-11100 Lite Outdoor
122 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Operating Instructions
LMS5xx
Electrical installation
8013796/ZM63/2017-05-09 © SICK AG · Germany · All rights reserved · Subject to change without notice 73
Chapter 6
LMS531 PRO Security Outdoor: Inputs” connection
LMS531 PRO Security Outdoor: “Alarm” connection
Pin Signal Funktion
1 A/DA (IN1) Armed/Disarmed (Switching input 1)
2 RD–/RxD Receiver RS-422/RS-232
3 GND IN Ground all inputs
4 GND RS/CAN Ground RS-422/RS-232/CAN
5 D/N (IN3) Day/Night (Switching input 3)
6 WT (IN2) Walk Test (Switching input 2)
7 TD–/TxD Transmitter RS-422/RS-232
8 TEACH (IN4) EasyTeach (Switching input 4)
9 RD+ Receiver RS-422
10 TD+ Transmitter RS-422
11 CAN L CAN bus low
12 CAN H CAN bus high
Tab. 34: LMS531 PRO Security Outdoor: Pin assignment of the “Inputs” connection (12-pin M12 male connector, A-coded)
10
11
12
6
5
4
7
8
9
1
2
3
Pin Signal Funktion
1 Alarm A Alarm output (relay), contact A
2 Sab A Sabotage output (relay), contact A
3 Alarm B Alarm output (relay), contact B
4 Alarm R A Alarm output, resistor monitored, contact A
5 Error A Error output (relay), contact A
6 Alarm R B Alarm output, resistor monitored, contact B
7 Disq. A Disqualification output (relay), contact A
8 Error B Error output (relay), contact B
9 Sab B Sabotage output (relay), contact B
10 Disq. B Disqualification output (relay), contact B
11 Sab R A Sabotage output , resistor monitored, contact A
12 Sab R B Sabotage output , resistor monitored, contact B
Tab. 35: LMS531 PRO Security Outdoor: Pin assignment of the “Alarm” connection (12-pin M12 female connector, A-coded)
10
11
12
6
5
4
7
8
9
1
2
3