Figure 90: Log in to SOPAS ET
To log in directly to the SDD, select Log in to device using the following icon.
Figure 91: Log in to the SDD
NOTE
After five invalid login attempts, subsequent login attempts are rejected for a period
of 30 seconds, even if they are entered correctly. After this time has elapsed, the
interlocking is automatically terminated and logging in is possible again.
Connection without login
•
The machine operator user level is displayed in the status bar (bottom left).
•
The device configuration cannot be changed. However, all settings can be read.
Connection after login with Maintenance
•
The Maintenance user level is displayed in the status bar (bottom left).
•
The device configuration can be read and changed.
Connection after registration with service
•
The service user level is displayed in the status bar (bottom left).
•
The device configuration can be read and changed.
•
The Service tab is also displayed in the interface if Expert is selected as the user
level (section 8.2.4).
8.2.4 Service settings (service user level)
Settings relevant to cybersecurity can be made in this tab.
All Ethernet services running on the device are displayed and can be activated and
deactivated there (see table 129):
Table 114: Ethernet services
Ethernet service Function Note
SOPAS communi‐
cation
Necessary for the connection to
SOPAS ET
If this service is deactivated, a con‐
nection via SOPAS ET is no longer
possible.