8.2.5.2 System settings for the EXPERT function level
I/O configuration
Figure 93: I/O configuration
You can view the MLG-2's output and the pin on the connection in this figure.
Beam numbering
On delivery, beam 1 is located on the connection side of the MLG-2. You can choose to
configure the MLG-2 so that the beam numbering begins at the top.
Figure 94: Beam numbering
This might be a good idea, for example, if you mount the MLG-2 with the connections
facing upward, but still want to measure height classification from the bottom.
NOTE
Beam numbering has consequences for the beam functions FBB, FBM, LBB, LBM, CBB,
CBM, RLC, and on the beam status.
NOTE
This affects measuring functions that have already been configured. In the example, a
height classification is configured with the 10th beam (blue).
Pushbutton lock
You can use the pushbutton lock to set two options for the teach-in button on the
device:
CONFIGURATION WITH SOPAS ET 8
8018748.1Q3I/2024-12-18 | SICK O P E R A T I N G I N S T R U C T I O N S | MLG-2 ProNet
109
Subject to change without notice