Released: A teach-in process can be triggered using the button.
•
Locked: The teach-in button is locked to prevent inadvertent actuation, for exam‐
ple.
Reset
You have the option to reset the MLG-2 to the factory settings.
If you reset to factory settings, you will lose all data that has already been configured.
NOTE
•
The factory settings are restored as soon as 1 is written.
•
The MLG-2 will be reset too. Therefore, the control reports, where necessary, an
error that the MLG-2 is no longer available.
•
The following applies after resetting to factory settings:
°
No process data such as beam functions or beam status is output.
°
The alignment aid is active.
°
A teach-in is required. All functions become available again only after a
successful teach-in process.
The Reset command sets the MLG-2 back to the factory settings.
Ethernet
In the Ethernet area, configure the TCP/IP settings of the configuration interface for
SOPAS ET.
First of all, select the DHCP or Static option from the Addressing mode field.
With the Static addressing mode, you can change the IP address, the subnet mask, and the
gateway address. The MAC address is also displayed.
NOTE
Only make changes if you know your network very well and you know what effect the
changes will have on the settings!
8.2.5.3 System settings for PROFIBUS
In the Address configuration area, you can enter the address in the PROFIBUS. You can
enter an address from 1 to 125 for the MLG-2.
Figure 95: Address configuration in SOPAS ET
NOTE
Only make changes if you are extremely familiar with your network, and if you know
what effect the changes will have on the settings!
8.3 Measuring and diagnostic functions for switching outputs
A measuring or diagnostic function can be configured for each switching output on the
MLG2. If the criteria configured for the function are met, this is signaled on the relevant
output.
8 CONFIGURATION WITH SOPAS ET
110
O P E R A T I N G I N S T R U C T I O N S | MLG-2 ProNet 8018748.1Q3I/2024-12-18 | SICK
Subject to change without notice