Figure 119: Setting the hole position with the mouse
Output settings
General options for switching outputs see "Advanced settings for the outputs",
page 124.
8.3.8 Diagnostics
As well as measuring functions, diagnostic functions can also be assigned to the
outputs. Depending on the configuration, the output will respond when certain faults
occur or when the teach-in quality or process quality fall below a configured percentage.
Diagnostic settings
•
Activate Qn in the event of the following error messages:
– Contamination
The output is activated when a contamination warning occurs.
– Electrical short-circuit
The output is activated when a short-circuit occurs in the wiring.
– Teach-in error
The output is activated when an error occurs during the teach-in process.
– Hardware error
The output is activated when an error occurs with the hardware. Possible
cause: LED defective, receiver element defective, etc.
– Synchronization error
Output is activated when there is an error in the connection to the server.
•
Activate Qn if the teach-in quality is under ... %
The output is activated when the teach-in quality falls below a certain percentage
(see "Teach-in", page 16).
You can define the percentage in increments of 1%.
•
Activate Qn if the process quality is under ... %
The output is activated when the process quality falls below a certain percentage
(see "Teach-in", page 16).
You can define the percentage in increments of 1%.
Output settings
General options for switching outputs see "Advanced settings for the outputs",
page 124.
8.3.9 Advanced settings for the outputs
For switching outputs, you can select the option Invert output.
8 CONFIGURATION WITH SOPAS ET
124
O P E R A T I N G I N S T R U C T I O N S | MLG-2 ProNet 8018748.1Q3I/2024-12-18 | SICK
Subject to change without notice