The value remains constant until another teach-in process is carried out.
Beam blanking (only in EXPERT function level)
If you do not want to evaluate certain beams for your application, you can exclude them
from the teach-in process.
Blank blocked beams as follows:
The beams from the MLG-2 that are not to be accounted for in the measurement must
be blocked.
Figure 127: Example of the blanking of blocked beams
1
Made beams
2
Blocked beams
3
Beams included in the measurement
4
Excluded beams
Click Blank all blocked beams.
The blocked beams will not be taken into account in the measurement.
Activate the Activate beam blanking for every teach-inoption too.
The blocked beams will be excluded from every teach-in process in the future.
NOTE
You will never be notified that beams are blocked during the teach-in process.
Blank made beams as follows:
CONFIGURATION WITH SOPAS ET