Figure 131: Selection of relevant rays
Control elements
°
Update: Single-shot for measurement with inserted material
°
Automatic selection: Selection of all beams with a transmission of less than
90%
°
Power: Beams with an energy level that is too low for reliable measure‐
ment are displayed in red. In this case, the sensitivity of the system can
be increased using the Powercontrol elements. A single-shot measurement
including updating of the display is then carried out automatically.
Confirm the selection of the beams and the power level with Next .
5. Material teach-in step 2:
See material teach-in step 1 using the second material.
6. Summary:
In this view, the recorded transmissions of the two taught-in materials are dis‐
played. If the difference in transmission between the two materials is sufficiently
large for a distinction to be made, the values can be confirmed with Finish .
For the best possible result, carry out a final teach-in by clicking on Next (recom‐
mended).
CONFIGURATION WITH SOPAS ET
8
8018748.1Q3I/2024-12-18 | SICK O P E R A T I N G I N S T R U C T I O N S | MLG-2 ProNet
133
Subject to change without notice