EasyManua.ls Logo

SICK MLG-2 ProNet - Energy Option (Only in EXPERT Function Level); Beam Evaluation; Blocked Beams Hold (BBH) Evaluation Mode

SICK MLG-2 ProNet
180 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
8.7.2 Energy option (only in EXPERT function level)
Deactivating the high-speed scan function
Since the high-speed scan function results in a higher current consumption, it can be
deactivated. In this case, the function cannot be activated again via the response time
slider.
8.8 Beam evaluation
8.8.1 Blocked Beams Hold (BBH) evaluation mode
Prerequisites
Expert function level
Notes
You can only select one of the following evaluation modes: Standard, Blocked
Beams Hold (BBH) or Lost Beams Hold (LBH)
You can select the Blocked Beams Hold (BBH) evaluation mode for one beam function
or for several beam functions simultaneously.
Description of operation
The Blocked Beams Hold (BBH) evaluation mode is activated by a trigger signal at the
hardware input or by a trigger command via the fieldbus. If this evaluation mode has
been activated, any beams that have been blocked are saved and displayed as blocked
beams. Once the evaluation mode is deactivated by a withdrawal of the trigger signal,
the blocked beams are reset to made beams.
You can select the Blocked Beams Hold (BBH) evaluation mode for each beam function
and for several beam functions simultaneously. This means that a beam function
for which the evaluation mode Blocked Beams Hold (BBH) has been parameterized is
calculated on the basis of this evaluation mode.
CONFIGURATION WITH SOPAS ET 8
8018748.1Q3I/2024-12-18 | SICK O P E R A T I N G I N S T R U C T I O N S | MLG-2 ProNet
143
Subject to change without notice

Table of Contents

Related product manuals