12 Technical data
12.1 Data sheet
General data
Table 121: MLG-2 data sheet – General data
Protection class III (EN 61140)
Enclosure rating IP 65 and IP 67 (EN 60529)
1)
Ambient operating temperature –30 … +55°C
Storage temperature –40 … +70°C
Vibration resistance 5g, 10…55Hz (EN 60068-2-6)
Shock resistance (EN 60068-2-27)
•
Single shock
•
Continuous shock
•
15g, 11ms
•
10g, 16ms
Electromagnetic compatibility According to EN61000-6-2 Interference immun‐
ity for industrial environments and EN61000-6-4
Emission standard for industrial environments
MTTF
MTBF
15years
15years
Dimensions see "Dimensional drawings", page 165
Weight Sender + receiver approx. 2kg/m + 0.1kg
Materials
•
Housing
•
Front screen
•
Aluminum, anodized
•
PMMA
1)
Do not use light grids outdoors unless protected (condensation will form).
Electrical specifications (for 24VDC and 25°C ambient temperature)
Table 122: MLG-2 data sheet – Electrical specifications
Supply voltage V
S
24VDC ± 20%
Residual ripple (within V
S
) <10%
Current consumption of sender
•
Typical
•
Maximum
•
With 3x high-speed scan
•
40mA + (0.1mA × number of beams)
•
<55mA + (0.1mA × number of beams)
•
<100mA + (0.1mA × number of beams)
Current consumption of receiver
•
Typical
•
Maximum
•
In Dust- and sunlight-resistant operat‐
ing mode, where a beam of 150klx is
sent to all receiver optics
•
60mA + (0.25mA × number of beams)
•
<80mA + (0.25mA × number of beams)
•
<80mA + (0.55mA × number of beams)
Output signal switching device
Table 123: MLG-2 data sheet – Switching outputs
Switching type
Push-pull
Logic level switching points
•
HIGH
•
LOW
•
V
S
– 3V
•
<3V
Maximum output current per output 100mA
12 TECHNICAL DATA
156
O P E R A T I N G I N S T R U C T I O N S | MLG-2 ProNet 8018748.1Q3I/2024-12-18 | SICK
Subject to change without notice