Output load per output
•
Capacitive
•
Inductive
•
100nF
•
1H
Response time see figure 149, page 160
Technical measurement data
Table 124: MLG-2 data sheet – Technical measurement specifications
Wavelength 850nm
Ambient light immunity
•
Standard operating mode
•
Dust- and sunlight-resistant operating
mode
1)
•
150,000lx (constant light, indirect)
•
150,000lx (constant light, direct and indirect)
Minimum detectable object for devices
with 5mm, 10mm, 20mm, 25mm,
30mm, 50mm beam separation
•
With normal measurement accuracy
•
With high measurement accuracy
•
In Transparent operating mode
•
Cross beam function
•
Beam separation + 4mm
•
Beam separation
•
Beam separation
2)
•
0.5 × beam separation + 4mm
Minimum detectable object for devices
with 2.5mm beam separation
•
With normal measurement accuracy
•
With high measurement accuracy
•
In Transparent operating mode
•
Cross beam function
•
Beam separation + 1mm
•
Beam separation
•
Beam separation
3)
•
0.5 × beam separation + 3.5mm
Beam separation 2.5mm, 5mm, 10mm, 20mm, 25mm, 30mm,
50mm
Number of beams 6…510
Detection height 140 ... 3,140mm
Limiting range 2.8m/4.2m/7m/12m/20.3m depending on
appliance type
4)
Operating range 2m/3m/5m/8.5m/14.5m depending on
device type
5)
Minimum sensing range
•
With parallel-beam function
•
With cross-beam function
•
0mm
•
0.2…1.20m (see table 125, page 158)
Initialization time after switch-on <3 s
Response time see "Response time and minimum presence time
without high-speed scan", page 160
Minimum presence time see "Minimum attenuation in Transparent Mode",
page 163
Cycle time 8…48µs per beam
6)
1)
Only possible for devices with <240 beams.
2)
For opaque objects. For transparent objects + 4mm
3)
For opaque objects. For transparent objects + 1mm
4)
In Dust- and sunlight-resistant operating mode depending on device type.
5)
In Dust- and sunlight-resistant operating mode: 3m/5m depending on device type.
6)
Depending on device version and operating mode.
TECHNICAL DATA 12
8018748.1Q3I/2024-12-18 | SICK O P E R A T I N G I N S T R U C T I O N S | MLG-2 ProNet
157