EasyManua.ls Logo

SICK MLG-2 ProNet - Page 157

SICK MLG-2 ProNet
180 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Output load per output
Capacitive
Inductive
100nF
1H
Response time see figure 149, page 160
Technical measurement data
Table 124: MLG-2 data sheet – Technical measurement specifications
Wavelength 850nm
Ambient light immunity
Standard operating mode
Dust- and sunlight-resistant operating
mode
1)
150,000lx (constant light, indirect)
150,000lx (constant light, direct and indirect)
Minimum detectable object for devices
with 5mm, 10mm, 20mm, 25mm,
30mm, 50mm beam separation
With normal measurement accuracy
With high measurement accuracy
In Transparent operating mode
Cross beam function
Beam separation + 4mm
Beam separation
Beam separation
2)
0.5 × beam separation + 4mm
Minimum detectable object for devices
with 2.5mm beam separation
With normal measurement accuracy
With high measurement accuracy
In Transparent operating mode
Cross beam function
Beam separation + 1mm
Beam separation
Beam separation
3)
0.5 × beam separation + 3.5mm
Beam separation 2.5mm, 5mm, 10mm, 20mm, 25mm, 30mm,
50mm
Number of beams 6…510
Detection height 140 ... 3,140mm
Limiting range 2.8m/4.2m/7m/12m/20.3m depending on
appliance type
4)
Operating range 2m/3m/5m/8.5m/14.5m depending on
device type
5)
Minimum sensing range
With parallel-beam function
With cross-beam function
0mm
0.2…1.20m (see table 125, page 158)
Initialization time after switch-on <3 s
Response time see "Response time and minimum presence time
without high-speed scan", page 160
Minimum presence time see "Minimum attenuation in Transparent Mode",
page 163
Cycle time 8…48µs per beam
6)
1)
Only possible for devices with <240 beams.
2)
For opaque objects. For transparent objects + 4mm
3)
For opaque objects. For transparent objects + 1mm
4)
In Dust- and sunlight-resistant operating mode depending on device type.
5)
In Dust- and sunlight-resistant operating mode: 3m/5m depending on device type.
6)
Depending on device version and operating mode.
TECHNICAL DATA 12
8018748.1Q3I/2024-12-18 | SICK O P E R A T I N G I N S T R U C T I O N S | MLG-2 ProNet
157
Subject to change without notice