Loading...
Table 125: Minimum sensing range with cross-beam function
Beam separation
MLG-2 with sensing
range
2.5mm 5mm 10mm 20mm 25mm 30mm 50mm
2m 0.20m
3m 0.20m - - - - - -
5m 0.11m 0.22m 0.44m 0.55m 0.66m 1.10m
8.5m 0.12m 0.24m 0.48m 0.60m 0.72m 1.20m
14.5m 0.12m 0.24m 0.48m 0.60m 0.72m 1.20m
12.2 Fieldbus module data sheet
General data
Table 126: Fieldbus module data sheet – General data
Protection class III (EN 61140)
Enclosure rating IP 65 and IP 67 (EN 60529)
1)
Ambient operating temperature –30…+55°C
Storage temperature –40 … +70°C
Vibration resistance 5g, 10…55Hz (EN 60068-2-6)
Shock resistance (EN 60068-2-27)
Single shock
Continuous shock
15g, 11ms
10g, 16ms
Electromagnetic compatibility According to EN61000-6-2 Interference immun‐
ity for industrial environments and EN61000-6-4
Emission standard for industrial environments
MTTF
MTBF
15 years
15 years
Firmware version See type label of device.
Dimensions see "Dimensional drawing for the MLG-2", page 165
Weight 350g
Materials
Housing
Zinc, painted
1)
Do not use light grids outdoors without protection (condensation will form).
Electrical specifications (for 24VDC and 25°C ambient temperature)
Table 127: Fieldbus module data sheet – Electrical specifications
Supply voltage V
S
24VDC ± 20%
Residual ripple (within V
S
) <10%
Current consumption
Typical
Maximum
115mA
<160mA
12 TECHNICAL DATA
158
O P E R A T I N G I N S T R U C T I O N S | MLG-2 ProNet 8018748.1Q3I/2024-12-18 | SICK
Subject to change without notice