12.3.2 Response time and minimum presence time for Highspeed Scan with 2.5mm raster
Distance between sender and receiver [m]
Minimum presence time [ms]
Response time [ms]
1
2
3
4
5
6
7
8
Figure 150: Response time and minimum presence time up to 2m sensing range
1
Detection height = 150mm MVD
2
Detection height = 300mm
3
Detection height = 450mm
4
Detection height = 600mm
5
Detection height = 750mm
6
Detection height = 900mm
7
Detection height = 1,050mm
8
Detection height = 1,200mm
NOTE
Only applies to the High measurement accuracy operating mode, as only this operating
mode can be set via the SDD, especially for 2.5mm raster devices.
TECHNICAL DATA 12
8018748.1Q3I/2024-12-18 | SICK O P E R A T I N G I N S T R U C T I O N S | MLG-2 ProNet
161