12.3.5 Minimum attenuation in Transparent Mode
10 % (14.5 m)
10 % (8.5 m)
10 % (5 m)
10 % (3 m)
10 % (2 m)
15 % (14.5 m)
15 % (8.5 m)
15 % (5 m)
15 % (3 m)
15 % (2 m)
30 % (14.5 m)
30 % (8.5 m)
30 % (5 m)
30 % (3 m)
30 % (2 m)
Minimum object attenuation (MDA) in %
0
5
10
15
20
25
30
35
40
45
50
0 2 4 6 8 10 12 14
Distance [m]
Figure 153: Required minimum attenuation for devices with 2m, 3m, 5m, 8.5m and 14.5m
sensing range
NOTE
The minimum detectable absorption which can be read from the diagram applies
after the teach-in process with clean ambient conditions. The minimum detectable
absorption increases with the level of contamination. Clean the front screens of the
sender and receiver regularly, then perform a teach-in process.
TECHNICAL DATA 12
8018748.1Q3I/2024-12-18 | SICK O P E R A T I N G I N S T R U C T I O N S | MLG-2 ProNet
163
Subject to change without notice