12.3.6 Minimum transmission difference for switching thresholds from material teach-in
0.2 m
0.4 m
0.6 m
0.8 m
1.0 m
Min. transmission difference
25 %
20 %
15 %
10 %
5 %
0 %
1 % 10 %
Basic transmission
100 %
Figure 154: Minimum transmission difference for a beam separation of 2.5 mm for different
spaces between sender and receiver
1
2
3
Min. transmission difference
25 %
20 %
15 %
10 %
5 %
0 %
1 % 10 %
Basic transmission
100 %
Figure 155: Minimum transmission difference for a beam separation of ≥5 mm for different
spaces between sender and receiver
1
0.2 m / 0.4 m / 0.6 m
2
0.8 m
3
1.0 m
NOTE
The values given for the minimum transmission difference are typical values.
Optimum alignment is a prerequisite for achieving this data. Regular teach-in is also
recommended.
The minimum transmission difference increases due to signal reduction, e.g. due to
contamination or an increasing working distance.