High-speed scan is not possible.
•
The minimum detectable object size with cross-beam function is also dependent
on the other performance options, such as the configured response time and
operating reserve. The precise minimum detectable object size is displayed in
SOPAS ET on the MLG-2 (see "Interface", page 95).
3.6.4 Minimum detectable object with high measurement accuracy from the MLG-2
When using the MLG-2, the measurement accuracy can be increased in SOPASET (see
"Performance options", page 135). This means that an object can be detected even if it
only covers half of a beam.
Figure 16: Minimum detectable object size with high measurement accuracy
1
Beam diameter
2
Object is reliably detected (meets requirements of minimum detectable object size)
Table 11: Minimum detectable object size with high measurement accuracy
Beam separation Minimum detectable object (stationary object)
1)
2.5mm 2.5mm
5mm 5mm
10mm 10mm
20mm 20mm
25mm 25mm
30mm 30mm
50mm 50mm
1)
Only if the object also meets the minimum detectable length requirements see table 9, page 21).
Minimum detectable object length
Table 12: Minimum detectable object length with high measurement accuracy
Beam separation Minimum detectable object length (stationary object)
1)
2.5mm 1mm
5 … 50mm 2mm
1)
Only if the object also meets the minimum detectable length requirements (see table 8, page 20).
•
When using high measurement accuracy to detect moving objects, the minimum
detectable object length also depends on the speed of the object and the
other performance options, such as the configured response time and operating
reserve. The precise minimum detectable object length is displayed in SOPAS ET
on the MLG-2 (see "Interface", page 95).
•
Sensing ranges larger than the operating range are not possible when using high
measurement accuracy.
•
High measurement accuracy can cause the operating reserve to decrease in the
event of large sensing ranges and imperfect alignment.