3.9.1 Interfaces
•
One interface for integration into a PROFIBUS fieldbus (see "The MLG-2 on the
PROFIBUS network", page 58)
•
An Ethernet interface for configuration with SOPAS ET (see "Configuration with
SOPAS ET", page 94)
•
One switching output (push-pull)
The functions of this switching output can be configured in SOPAS ET (see "Meas‐
uring and diagnostic functions for switching outputs", page 110). These functions
can also be configured using PROFIBUS.
3.9.2 Configurable functions
The functions of the MLG-2 can be configured using SOPASET or via the respective
fieldbus. The tables below show which application is used to configure each function.
Table 13: Functions available for or during teach-in
Name Function Available for
SOPAS ET Fieldbus
Teach-in Starts a teach-in
C C
Teach-in result Result of the teach-in
C C
Teach-in required Teach-in required for further operation
C C
Teach-in with blank‐
ing
Activate beam blanking for each teach-in
C C
Auto teach-in Starts a teach-in every time when switching
on
C
–
Blanks blocked
beams
Excludes all blanking beams during the
teach-in
C C
Blanks beams
made
Excludes all beams made during the teach-in
C C
Beam mask Any defined beams will be excluded from the
measurement.
In SOPAS ET by clicking the mouse
In the fieldbus via a bit-coded beam mask
C C
NOTE
The information in the MLG-1 operating instructions (8014134) available at
www.sick.comapplies for the FBM-P22 fieldbus module.
Table 14: Functions available for operating modes and performance options
Name Description Available for
SOPAS ET Fieldbus
Operating mode Selection of the operating mode
C C
Performance
options
Defines the performance options
C
C
Minimum detecta‐
ble absorption
Sets the minimum detectable absorption for
Transparent operating mode
C
C
Energy saving
mode
Puts the MLG-2 on standby
C C
Scanning method Defines the parallel beam function, cross
beam function or high-speed scan.
C
1)
C
1)
Configuration Q1 Function programming for switching output
Q1
C C
Alarm Q1 Defines various diagnostic settings for Q1
C
–
3 PRODUCT DESCRIPTION
26
O P E R A T I N G I N S T R U C T I O N S | MLG-2 ProNet 8018748.1Q3I/2024-12-18 | SICK
Subject to change without notice