Table 17: System information
Name Description Available for
SOPAS ET Fieldbus
Device name “MLG-2 ProNet” device name
C C
Manufacturer
name
“SICK AG” manufacturer name
C C
Part number Part number of the MLG-2
C C
Serial number Serial number of the MLG-2
C C
Product text Description of the MLG-2
C C
Mounting location Option to enter the mounting location
C C
Device characteris‐
tics
Display of the device characteristics and sys‐
tem boundaries
C C
Hardware revision Status of the hardware
C C
Firmware version The version of firmware
C C
Table 18: Beam evaluation
Name Description Available for
SOPAS ET Fieldbus
Zone measuring Combines beams into zones and assigns
them to a beam function and an output
C C
Cross beam meas‐
uring
Activates the “Cross beam measuring” func‐
tion
C C
Blocked Beams
Hold
Evaluation mode for all selected beam func‐
tions
C C
Lost Beams Hold Evaluation mode for all process data
C C
Table 19: Settings for the interfaces
Name Description Available for
SOPAS ET Fieldbus
IP address Defines the IP address for the configuration
interface
C
–
MAC address Displays the MAC address for the configura‐
tion interface
C
–
Subnet mask Defines the subnet mask for the configura‐
tion interface
C
–
Gateway address Defines the gateway address for the configu‐
ration interface
C
–
DHCP Activates DHCP for the configuration inter‐
face
C
–
Table 20: Settings for SOPAS ET
Name
Description Available for
SOPAS ET Fieldbus
Rotate the MLG-2
display
Rotates the display of the MLG-2 on the
SOPAS interface
C
–
Function level Defines the function level in SOPAS ET
C
–
3.9.3 Available process data
The MLG-2 provides a series of process data. The following table shows which process
data is available for the individual applications.
3 PRODUCT DESCRIPTION
28
O P E R A T I N G I N S T R U C T I O N S | MLG-2 ProNet 8018748.1Q3I/2024-12-18 | SICK
Subject to change without notice