1
Two MLG-2s, one behind the other
2
Two MLG-2s, one above the other
3
Two MLG-2s, one next to the other
NOTE
When two MLG-2s are placed opposite one another and their light beams are in
opposite directions,1 reflections may occur from sender 1 to receiver 2 in the case of
shiny objects.
4.2.2 Mounting with light in the same direction
When several MLG-2s are mounted with their light beams oriented in the same direc‐
tion, a minimum distance must be maintained between the MLG-2s. The minimum
distance increases as the distance between the sender and receiver increases and is
dependent on the operating range.
Figure 29: Distances when light is in the same direction
X Operating range
Y Minimum distance of the MLG-2
Z Minimum distance of the MLG-2
4 MOUNTING
36
O P E R A T I N G I N S T R U C T I O N S | MLG-2 ProNet 8018748.1Q3I/2024-12-18 | SICK
Subject to change without notice

Table of Contents