Test inputs solution
Activate the test inputs of both senders alternately. The beams will be switched off in
each case for as long as the test input is active.
Mounting solution
Mount the two MLG-2 as far apart as possible.
4.2.4 Minimum distance from reflective surfaces
Reflective surfaces between the sender and receiver may result in disruptive reflections
and beams being deflected and, hence, result in a failure to detect objects.
In the case of reflective surfaces, a minimum distance must be maintained between
the reflective surface and the light beams to ensure reliable operation.
This minimum distance depends on the distance between sender and receiver and on
the operating range.
MOUNTING 4
8018748.1Q3I/2024-12-18 | SICK O P E R A T I N G I N S T R U C T I O N S | MLG-2 ProNet
39
Subject to change without notice