EasyManua.ls Logo

SICK MLG-2 ProNet - Mounting Procedure

SICK MLG-2 ProNet
180 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
1
2
3
4
Figure 33: Graph, minimum distance from reflective surfaces
1
MLG-2 with 2m and 3m range
3)
2
MLG-2 with 2m and 3m range
4)
3
MLG-2 with 5m range
5)
4
MLG-2 with 8.5m and 14.5m range
5)
This distance also applies to reflective surfaces located next to the light grid (parallel to
the sending/receiving axis).
4.3
Mounting procedure
Mount the sender and receiver at the same height. For minor adjustments when
aligning, the sender and receiver can be adjusted in the brackets.
If possible, mount the top bracket at a height such that the offset in the housing of
the MLG-2 sits on the bracket. This prevents the MLG-2 from sliding down.
3)
Applies to specular surfaces parallel to the housings
4)
Applies to specular surfaces perpendicular to the housings
5)
Applies to specular surfaces parallel and perpendicular to the housings
4 MOUNTING
40
O P E R A T I N G I N S T R U C T I O N S | MLG-2 ProNet 8018748.1Q3I/2024-12-18 | SICK
Subject to change without notice

Table of Contents