Figure 37: Mounting the FlexFix bracket on a profile frame
Screwing the sender or receiver into the FlexFix brackets
After mounting the FlexFix brackets, screw the sender or receiver into the FlexFix
brackets from the front. Then align the sender and receiver.
NOTE
The MLG-2 can only be screwed in when both FlexFix brackets are in alignment. If
necessary, use a water level to check the components are parallel.
Figure 38: Inserting the MLG-2 in the FlexFix brackets
►
Use an M5 screw to fix the position of the sender and receiver in the FlexFix
bracket.
Mounting bracket for the fieldbus module
If you are using the FlexFix bracket, you will need a mounting bracket for the fieldbus
module.