5 Electrical installation
CAUTION
De-energize the system!
The system could inadvertently start while you are connecting the devices.
►
Make sure that the entire system is disconnected from the power supply during
the electrical installation work.
NOTE
•
The MLG-2 complies with the EMC regulations for the industrial sector (Radio
Safety Class A). It may cause radio interference if used in a residential area.
•
Do not lay cables parallel to other cables, especially not to devices with a high
level of radiated emission, such as a frequency converter.
•
When using cables over 15m in length, or in locations with a high level of
interference, we recommend using a T-distributor in order to connect the sender
and receiver via a short synchronization cable wherever possible.
5 ELECTRICAL INSTALLATION
48
O P E R A T I N G I N S T R U C T I O N S | MLG-2 ProNet 8018748.1Q3I/2024-12-18 | SICK