5.1 Fieldbus module connections
BUS OUT
CONFIG
BUS IN
POWER
DEVICE
1
2
3
4
5
Figure 44: Fieldbus module connections
1
CONFIG – Ethernet connection for configuring via PC/notebook
2
BUS OUT - Serial connection of the fieldbus
3
BUS IN - Serial connection of the fieldbus
4
POWER – Power supply connection
5
DEVICE - Connection for the MLG-2
NOTE
Protect all unused connections with a plastic cap!
CONFIG connection
Table 23: Pin assignment, MLG-2 fieldbus connection box, CONFIG
Female connector Pin Signal Meaning
3
2
4
1
1 TX+ Ethernet
2 RX+ Ethernet
3 TX– Ethernet
4 RX– Ethernet
ELECTRICAL INSTALLATION 5