Figure 48: Alignment with the FlexFix bracket
6.2
Alignment and teach-in
To ensure the alignment aid works perfectly, the device should be rotated once from the
left bracket stop to the right stop. This makes the best possible settings for the input
sensitivity and ensures that the alignment aid shows the most helpful values.
Figure 49: Rotate the receiver once
The yellow LED on the front of the receiver and the Alignment LED show the rough
alignment.