7.4.1.5 Blank blocked beams
Table 81: Blank blocked beams
Index Access Data type Description
44h R/W BOOL This parameter is used to blank the blocked
beams for later measurements.
0 = no blanking
1 = blank the beams
A change from 0 to 1 always initiates a blank‐
ing of blocked beams. If the beams are to be
blanked again, this index must first be descri‐
bed using 0.
The beams from the MLG-2 that are not to be accounted for in the measurement must
be blocked.
Figure 68: Example of the blanking of blocked beams
1
Made beams
2
Blocked beams
3
Beams included in the measurement
4
Excluded beams
7.4.1.6 Blank beams made
Table 82: Blank beams made
Index Access Data type Description
45h R/W BOOL This parameter is used to blank the made
beams for later measurements.
0 = no blanking
1 = blank the beams
A change from 0 to 1 always initiates a blank‐
ing of beams made. If the beams are to be
blanked again, this index must first be descri‐
bed using 0.