Figure 69: Example of blanking made beams
1
Made beams
2
Blocked beams
3
Beams included in the measurement
4
Excluded beams
The made beams will not be taken into account in the measurement.
7.4.1.7 Beam mask
Table 83: Beam mask
Index Access Data type Description
46h…55h R UINT-32 These parameters are used to blank the
beams from the MLG-2 for measurement pur‐
poses.
46h contains beams 1 … 32
47h contains beams 33 … 64
55h contains beams 481 … 512
0 = beam is blanked
1 = beam is included in the measurement
The beams can be blanked using a bit-coded beam mask. This example shows the
bit-coded beam mask for an MLG-2, with 30 beams.
Figure 70: Bit-coded beam mask for an MLG-2, with 30 beams
THE MLG-2 ON THE PROFIBUS NETWORK
7
8018748.1Q3I/2024-12-18 | SICK O P E R A T I N G I N S T R U C T I O N S | MLG-2 ProNet
81
Subject to change without notice