Table 110: Zone measuring
Index Access Data type Description
90h R/W UINT-16 Zone 1 First Beam: Sets lower zone boundary
for Zone 1
91h R/W UINT-16 Zone 1 Last Beam: Sets upper zone boundary
for Zone 1
92h R/W UINT-16 Zone 2 First Beam: Sets lower zone boundary
for Zone 2
93h R/W UINT-16 Zone 2 Last Beam: Sets upper zone boundary
for Zone 2
94h R/W UINT-16 Zone 3 First Beam: Sets lower zone boundary
for Zone 3
95h R/W UINT-16 Zone 3 Last Beam: Sets upper zone boundary
for Zone 3
96h R/W UINT-16 Zone 4 First Beam: Sets lower zone boundary
for Zone 4
97h R/W UINT-16 Zone 4 Last Beam: Sets upper zone boundary
for Zone 4
7.4.5.2 Cross beam measuring
Table 111: Cross beam measuring
Index Access Data type Description
98h R/W BOOL If the cross beam function option is activated
via object 61h power options, you can use
this object to choose between the cross beam
measuring or cross beam switching options.
0 = Cross beam measuring function deacti‐
vated. Cross beam switching function active.
1 = Cross beam measuring function activated.
7.4.5.3 BBH and LBH evaluation modes
For a description of the “Blocked Beams Hold (BBH)” evaluation mode, see "Blocked
Beams Hold (BBH) evaluation mode", page 143
For a description of the “Lost Beams Hold (LBH)” evaluation mode, see "Lost Beams
Hold (LBH) evaluation mode", page 144
Table 112: Evaluation mode
Index Access Data type Description
99h R/W ENUM-8 This parameter is used to select an evaluation
mode.
0: OFF, no BBH mode or LBH mode active
1: BBH mode active
2: LBH mode active
7 THE MLG-2 ON THE PROFIBUS NETWORK
92
O P E R A T I N G I N S T R U C T I O N S | MLG-2 ProNet 8018748.1Q3I/2024-12-18 | SICK
Subject to change without notice