8.2 Operation SOPAS ET
8.2.1 Interface
In the upper part of the interface, you can change the type of MLG-2, the operating
mode and the function level.
Figure 72: Device selection, operating mode and function level
Device selection
If you carry out the configuration offline (without a connected MLG-2), you can change
the MLG-2 type via the button shown on the left.
If the MLG-2 is online, the type code of the MLG-2 will be displayed.
Operating modes
The MLG-2 has the following operating modes:
Standard
For normal measuring tasks involving opaque objects (recommended for the
majority of applications)
Transparent
For transparent objects, e.g., made of glass, PET, etc.
Dust- and sunlight-resistant
For applications when there is a large amount of dust in the environment or a high
level of solar radiation
NOTE
When the operating mode is changed, a new teach-in process must be performed.
The choice of operating mode affects the performance options.
Function level
The configuration is divided into two function levels.
The function level EASY only shows the absolutely necessary parameters and leads
quickly to the target. This level is automatically activated when SOPAS ET starts up.
For users with experience or more complex requirements, the function level EXPERT is
available, where all parameters can be configured.
CONFIGURATION WITH SOPAS ET