The minimum detectable object (MDO) and the minimum detectable object length
(MOL) are specified in millimeters as well as shown graphically.
The system boundaries are largely dependent on the configured performance options
(see "Performance options", page 135).
Wizards
Figure 75: Wizards
You can start the Installation Wizard or Application Wizard under Wizards.
•
The Installation Wizard helps you to align the MLG-2 and carry out the teach-in
process.
•
The Application Wizard helps you to configure the settings for the outputs. Only
the necessary adjustments for the MLG-2 are offered, according to the choice of
application.
Recommendation
Use this wizard for the initial configuration of a device. The separate adjustments avail‐
able in the main interface allow the user to make specific changes to the configuration.
Teach-in status
If a teach-in becomes necessary because of a change to a parameter, the LED symbol
will light red, indicating teach-in required.
Process quality
Figure 76: Display of the process quality
SOPAS ET shows the process quality as a percentage and as a colored bar.
Interface status
SOPAS ET displays the communication status via the respective interface.
•
Green = communication active
•
Gray = communication not active
Device status
SOPAS ET displays the device status via a colored indicator and in the form of plain text:
•
Green = MLG-2 functions reliably
•
Yellow = warning pending
•
Red = error has occurred
8.2.1.2 Basic functions and status of the output
Basic functions
Under Basic functions, you will find the following information:
CONFIGURATION WITH SOPAS ET 8
8018748.1Q3I/2024-12-18 | SICK O P E R A T I N G I N S T R U C T I O N S | MLG-2 ProNet
97
Subject to change without notice