30
SICK MSL
8 007 653/09-04-01 Technical Description • MSL © SICK AG • Safety Systems • Germany • All rights reserved
12 MSL selection table
12 MSL selection table
MSL sender unit
The part no. of the MSL
with/without external contact
monitoring
with/without restart inhibit
are available upon request.
Connector system must be
ordered separately.
Standard equipment is PG
connector.
Sender
Beams Beam gap Scanning range Type Part no.
mm m
2 500 0,5 ... 20 MSLS 02-15021 1 013 748
2 500 15 ... 70 MSLS 02-15011 1 012 295
3 220 0,5 ... 20 MSLS 03-12221 1 013 749
3 220 15 ... 70 MSLS 03-12211 1 013 763
3 400 0,5 ... 20 MSLS 03-14021 1 013 750
3 400 15 ... 70 MSLS 03-14011 1 013 746
Access guarding
Sender
Beams Resolution Scanning range Type Part no.
mm m
20 93 0,5 ... 20 MSLS 20-10721 1 016 067
20 93 15 ... 70 MSLS 20-10711 1 015 702
23 93 0,5 ... 20 MSLS 23-10721 1 015 924
23 93 15 ... 70 MSLS 23-10711 1 015 866
14 73 0,5 ... 20 MSLS 14-10521 1 016 529
14 73 15 ... 70 MSLS 14-10511 1 016 522
17 73 0,5 ... 20 MSLS 17-10521 1 016 530
17 73 15 ... 70 MSLS 17-10511 1 016 523
20 73 0,5 ... 20 MSLS 20-10521 1 016 531
20 73 15 ... 70 MSLS 20-10511 1 016 524
23 73 0,5 ... 20 MSLS 23-10521 1 016 391
23 73 15 ... 70 MSLS 23-10511 1 016 390
26 73 0,5 ... 20 MSLS 26-10521 1 016 532
26 73 15 ... 70 MSLS 26-10511 1 016 525
29 73 0,5 ... 20 MSLS 29-10521 1 016 533
29 73 15 ... 70 MSLS 29-10511 1 016 526
32 73 0,5 ... 20 MSLS 32-10521 1 016 534
32 73 15 ... 70 MSLS 32-10511 1 016 527
35 73 0,5 ... 20 MSLS 35-10521 1 016 535
35 73 15 ... 70 MSLS 35-10511 1 016 528
Area guarding