Motor Components (Options)
4.4 Motors without DRIVE-CLiQ
Connection assignment for 12–pin flange-mounted socket with pin contacts
Table 4-10 Connection assignment for 12–pin flange-mounted socket
PIN No. Signal
1 S2
2 S4
3 not connected
4 not connected
5 not connected
6 not connected
7 R2/R3
8 +Temp
9 –Temp
10 R1
11 S1
12 S3
2
1
10
12
11
6
3
9
8
7
4
5
When viewing the plug-in side (pins)
Cables
Table 4-11 Prefabricated cable
6FX ☐ 002 - 2CF02 - ☐☐☐ 0
↓
↓
5 MOTION-
CONNECTⓇ500
8 MOTION-
CONNECTⓇ800
↓↓↓
Length
2-pole resolver: Max. cable length 50 m
Multi-pole resolver: Max. cable length 130 m
Additional technical data and length code, refer to Catalog, Chapter "MOTION-CONNECT
connection system"
1FT6 synchronous motors
Configuration Manual, (PFT6), Edition 12.2004, 6SN1197-0AD12-0BP0