Electrical Connections
2.2 Power connection
2.2.3 Connection through a terminal box
The terminal assignment in the terminal box must be implemented according to the
diagram.
The protective conductor must be connected.
Cable lugs acc. to DIN 46234 must be used.
Connect-up an optional brake (refer to the diagram).
Notice
Motors with a rated power of more than 100 kW must be grounded using the additional
M12 grounding stud provided at the NDE bearing endshield.
Figure 2-3 Terminal assignment in the terminal boxes
1FT6 synchronous motors
Configuration Manual, (PFT6), Edition 12.2004, 6SN1197-0AD12-0BP0
2-3