Basic functions
4.2 Homing
Connection of the SINAMICS S120 to the Technology CPU
104 Product Information, 09/2011, A5E00480378-04
4.2 Homing
4.2.1 Homing possibilities
Introduction
The "Homing" function is used to align the actual value of an encoder with the position of the
machine after the supply power is switched on or after the replacement of the encoder.
Where as incremental encoders must be homed after each restart of the system, absolute
encoders normally only need to be homed after a replacement of the encoder or the twisting
of the spindle without encoder.
The following homing possibilities exist:
Active homing
Passive homing
Direct homing
Active homing
A special traversing motion is executed for this type of homing.
Any running active motion command will be cancelled.
The following homing modes can be set in S7T Config:
Homing with reference cam and encoder zero mark
Homing only with reference cam
Homing only with encoder zero mark
Correct position value
Correct internal axis coordinate system
Passive homing
The homing does not cause any motion of the axis in this case.
Any running motion commands will not be affected.
The following homing possibilities exist:
Homing with reference cam and encoder zero mark
Homing only with reference cam
Homing with only encoder zero mark.

Table of Contents

Other manuals for Siemens 6ES7 305-1BA80-0AA0

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens 6ES7 305-1BA80-0AA0 and is the answer not in the manual?

Siemens 6ES7 305-1BA80-0AA0 Specifications

General IconGeneral
BrandSiemens
Model6ES7 305-1BA80-0AA0
CategoryController
LanguageEnglish

Related product manuals