EasyManua.ls Logo

Siemens 6SE2101–1AA01 - 2. TECHNICAL DATA; 2.1 Equipment Ratings Table

Siemens 6SE2101–1AA01
110 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
English2/1
Siemens plc 1993
2. TECHNICAL DATA
Rated supply voltage:
V 1AC 50/60 Hz +/–1% 220 – 240 V +/–10%Models 6SE21**–1AA01
3AC 50/60 Hz +/–1% 380 – 500 V +/–10%Models 6SE21**–3AA01 V
Output voltage
Output frequency
Efficiency
Motor Power Factor
Ambient temperature (operation)
(unit must not be exposed to direct sunlight)
Storage/transport temperature
Degree of protection
Humidity
Frequency stability at
Frequency resolution
V
Hz
Hz
0 – Rated supply voltage
0.0 – 400
>
_
0.94
<
_
0.9 lagging/inductive
0 – 40
–30 to +85
IP21 (NEMA 1)
Analogue set–point 1%
Digital set–point 0.01%
0.1
Overload rating 1.5 x rated current for up to 60 seconds
Model No. Input Voltage Range
hp
6SE2101–1AA01
6SE2102–1AA01
6SE2103–1AA01
6SE2103–3AA01
6SE2105–3AA01
6SE2108–3AA01
198–264 V 1 Phase
198–264 V 1 Phase
198–264 V 1 Phase
342–550 V 3 Phase
342–550 V 3 Phase
342–550 V 3 Phase
7 A
11 A
18 A
4 A
8 A
12 A
10 A
16 A
20 A
6 A
10 A
16 A
2.8 A
3.9 A
6.8 A
4.0 A
7.6 A
0.75
1
2
2
5
7.5
0.55
0.75
1.5
1.5
3.0
5.5
2
Siemens 4–pole motor, 1LA5 Series or equivalent
1
0 – 95% at 25
o
C
T
max
10
o
C
The inverters will operate satisfactorily with unscreened cables of up to 100 m (330 ft) in length and screened
or armoured cable of up to 10 m (33 ft) in length. For applications where longer cables are required, inductors
must be fitted to reduce capacitive currents. The following chokes are suitable for most applications:
Model No.
Choke Type Inductance
6SE210*–1AA01 4EP3601–3DB 3 x 1.4 mH
6SE210*–3AA01 4EP3601–8DB 3 x 1.8 mH
6SE211*/6SE212*–3AA01 4EP3800–4DB 3 x 0.7 mH
6SE213*/6SE214*–3AA01 4EP4000–4DB 3 x 0.45 mH
2.2 Cable Lengths
2.1 Equipment Ratings Table
o
C
o
C
Typical
Motor
Rating
1
12/11 A
2
n
1
/n
2
n
1
= Current rating at 342 – 440 V
n
2
= Current rating at 440 – 550 V
referred to f
max
**
– May be any number
kW
6SE2113–3AA01
6SE2117–3AA01
342–550 V 3 Phase 23 A 25 A 10 7.5
342–550 V 3 Phase 30 A 32 A 15 11
Dist. Fuse/
Circuit
Breaker
3
6SE2122–3AA01
6SE2127–3AA01
342–550 V 3 Phase
342–550 V 3 Phase
34 A
40 A
40 A
50 A
20
25
15
18.5
6SE2133–3AA01
6SE2142–3AA01
342–550 V 3 Phase 54 A 63 A 30 22
342–550 V 3 Phase 71 A 80 A 40 30
38/34 A
2
19 A
25 A
32 A
46 A
60/52 A
2
Max.
Output
Current
Max.
Input
Current
Do not use semiconductor protection fuses
3

Table of Contents