English7/8
Siemens plc 1993
15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0
Data Byte 6 Data Byte 5
0 Not in STOPPED Mode
0 OFF
1 In RUNNING Mode
1 Tripped
0 Going to LOCKED Mode
1 In STOPPED Mode
0 Going to LOCKED Mode
1 In LOCKED Mode
Unused
1 Output freq = Desired freq
1 Serial Control
15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0
Data Byte 8 Data Byte 7
Parameter Value
or Current
1 ON
0 Not in RUNNING Mode
(free wheel)
(ramp down)
0 Manual Control
1 Output freq >= Desired freq
0 Forward
1 Reverse
Unused
or Fault Code