Incorporation in conductive pipe section
Inlet section
Outlet section
10 x DN (DN ≤ 1200/48")
5 x DN (DN > 1200/48")
5 x DN (DN ≤ 1200/48")
3 x DN (DN > 1200/48")
Flow conditions Developed flow profile
Table 10-2 Additions in the event of deviations from reference conditions
Current output As pulse output ± (0.1% of actual flow + 0.05% FSO)
Effect of ambient temperature
Display/frequency/pulse output
Current output
< ± 0.003% / °C act.
< ± 0.005% / °C act.
Effect of supply voltage < 0.005% of measuring value on 1% change
Repeatability ± 0.1% of actual flow for V ≥ 0.5 m/s (1.5 ft/s) and con‐
ductivity ≥ 10 μS/cm
10.3 Output characteristics
Current output
Output characteristics Bidirectional mode Unidirectional mode
0 to 20 mA
*
P$
&XW
RII
4
&XW
RII
4
P$
*
4 to 20 mA
*
P$
4
&XW
RII
&XW
RII
P$
4
*
Frequency output
Bidirectional mode Unidirectional mode
*
)>+]@
)PD[
&XW
RII
4
&XW
RII
)>+]@
)PD[
4
*
Technical data
10.3 Output characteristics
SITRANS FM MAG 5000/6000 IP67
72 Operating Instructions, 12/2019, A5E02338368-AD