DN Q
max*
Factory sett‐
ting
MAG 5100 W (Order no. 7ME6520) MAG 1100, MAG 1100 F, 5100 W
(Order no. 7ME6580), MAG 3100,
3100 P
unit
mm (inch) min. max. min. max.
800 (32) 7000 452.3894 18095,57 452.3894 18095.57 m
3
/h
900 (36) 9000 572.5553 22902,21 572.5553 22902.21 m
3
/h
1000 (40) 12000 706.8584 28274.33 706.8584 28274.33 m
3
/h
1050 (42) 12000 706.8584 28274.33 706.8584 28274.33 m
3
/h
1100 (44) 14000 855.986 34211.94 855.2986 3421194 m
3
/h
1200 (48) 15000 1017.877 40715.04 1017.877 40715.04 m
3
/h
1400 (54) 25000 - - 1385.443 55417.69 m
3
/h
1500 (60) 30000 - - 1590.432 63617.25 m
3
/h
1600 (66) 35000 - - 1809.558 72382.29 m
3
/h
1800 (72) 40000 - - 2290.222 91608.84 m
3
/h
2000 (78) 45000 - - 2827.434 113097.3 m
3
/h
2200 (90) 50000 - - 3421,195 136847.7 m
3
/h
2400 (96) 55000 - - 4071.505 162860.1 m
3
/h
2600 (102) 60000 - - 4778.363 191134.4 m
3
/h
280 (114) 65000 - - 5541.77 221670.7 m
3
/h
3000 (120) 70000 - - 6361.726 254469 m
3
/h
* The min. and max. amount values show mathematical values and do not indicate
measurement accuracy
C.3 60 Hz Dimension dependent Qmax
Table C-2 MAG 1100, MAG 1100 F, MAG 3100, MAG 3100 P and MAG 5100 W with ½" NPT cable glands
DN Q
max
.
Factory set‐
ting*
MAG 5100 W (Order no. 7ME6520) MAG 1100, MAG 1100 F, 5100 W
(Order no. 7ME6580), MAG 3100,
3100 P
unit
mm (inch) min. max. min. max.
2 (
1
/
12
) 0.14 - - 0.01718714 0.6874852 US GPM
3 (
1
/
8
) 0.31 - - 0.02800984 1.120393 US GPM
6 (
1
/
4
) 1.4 - - 0.1120394 4.481573 US GPM
10 (
3
/
8
) 4 - - 0.3112204 12.44881 US GPM
15 (½) 9 - - 0.7002459 28.0 US GPM
25 (1) 23 1.945128 77.80509 1.945128 77.80509 US GPM
40 (1½) 53 4.979526 199.181 4.979526 199.181 US GPM
50 (2) 89 6.932434 277.2973 7.78051 311.2203 US GPM
65 (2½) 133 11.00577 440.2305 13.14907 525.9624 US GPM
80 (3) 221 17.62753 705.1008 19.91811 796.7241 US GPM
Factory settings
C.3 60 Hz Dimension dependent Qmax
SITRANS FM MAG 5000/6000 IP67
98 Operating Instructions, 12/2019, A5E02338368-AD