Installing/mounting
4.2 Installation location requirements
SITRANS LR250 with mA/HART
Operating Instructions, 10/2019, A5E32220602-AG
27
Process temperature (at process connection)
Process connection tag (contains process connection related information)
Horn -40 to +80 °C
(-40 to +176 °F)
with FKM O-ring:-40 to +200 °C (-40 to
with FFKM O-ring:-20 to +200 °C (-4 to
PVDF and alumi-
num/polypropylene lens
-40 to +80 °C
(-40 to +176 °F)
-40 to +80 °C
(-40 to +176 °F)
PTFE flanged encapsulat-
-40 to +80 °C
-40 to +170 °C
Hygienic encapsulated -40 to +80 °C
(-40 to +176 °F)
-40 to +170 °C
with FKM seals used on process connection:
-20 to +170 °C (-4 to +338 °F)
with EPDM seals used on process connec-
tion:
-40 to +120 °C (-40 to +248 °F)
Note
Details about the process connection, process temperature and materials are laser etched
into the body of the flanged and hygienic versions. All other SITRANS LR250 versions have