Power Relay (for Direct Control of Motor Switches)
Switching capacity for permanent and periodic operation
250 V/4.0 A
220 V/4.5 A
110 V/5.0 A
60 V/5.0 A
48 V/5.0 A
24 V/5.0 A
1000 W
1000 W
550 W
300 W
240 W
120 W
In order to prevent any damage, the external protec-
tion circuit must switch off the motor in case the rotor
is blocked.
Turn on switching power for 30 s, recovery time until switching on again is 15 minutes.
For short-term switching operations, an impulse/pause ratio of 3 % must be considered.
100 V/9.0 A
60 V/10.0 A
48 V/10.0 A
24 V/10.0 A
1000 W
600 W
480 W
240 W
Continuous and inching operation is not permitted.
In order to prevent any damage, the external protec-
tion circuit must switch off the motor in case the rotor
is blocked.
AC and DC contact voltage 250 V
Permissible continuous current per contact 5 A
Permissible current per contact (switching on and
holding)
30 A for 1 s
Short-time current across closed contact 250 A for 30 ms
Total permissible current for contacts connected to
common potential
5 A
Switching time OOT (Output Operating Time)
Additional delay of the output medium used
≤ 16 ms
Rated data of the output contacts in accordance with
UL certification
DC 300 V, 4.5 A - 30 s ON, 15 min. OFF
DC 250 V, 1 hp motor - 30 s ON, 15 min OFF
DC 110 V, 3/4 hp motor - 30 s ON, 15 min OFF
DC 60 V, 1/2 hp motor - 30 s ON, 15 min OFF
DC 48 V, 1/3 hp motor - 30 s ON, 15 min OFF
DC 24 V, 1/6 hp motor - 30 s ON, 15 min OFF
Interference suppression capacitors across the
contacts
4.7 nF, ± 20 %, AC 250 V
The power relays operate in interlocked mode, that is, only one relay of each switching pair picks up at a time
thereby avoiding a power-supply short circuit.
Design Data
Masses
Device Size
Weight of the Modular Devices
Type of construction 1/3 1/2 2/3 5/6 1/1
Flush-mounting device 4.4 kg 7.2 kg 9.9 kg 12.7 kg 15.5 kg
Surface-mounted device with inte-
grated on-site operation panel
7.4 kg 11.7 kg 15.9 kg 20.2 kg 24.5 kg
Surface-mounted device with
detached on-site operation panel
4.7 kg 7.8 kg 10.8 kg 13.9 kg 17.0 kg
Size Weight
Detached on-site operation panel 1/3 1.9 kg
Detached on-site operation panel 1/6 1.1 kg