SIEMENS PTE LTD
C62 Level 2 Service Manual
Copyright © Siemens Pte Ltd. C62 Level 2 manual V1.1
All Rights Reserved
ICM MP CCQ SLI RHQ 17 of 47 Internal Use Only
Step 7 (Speaker)
Carefully fit the speaker into the speaker
housing in the B-cover. Press the speaker to
ensure it fits properly in the B-cover.
Step 8
Place the speaker gasket onto the speaker.
The gasket must be replaced if it is even
slightly damaged!
Step 9
Detach the protection foil from the new audio
cap.
Step 10
Place the audio cap on the speaker. The
two pins (marked with arrows) align the
audio cap in its correct place.
Step 11
Press the audio cap to ensure it is properly
glued into place. Make sure the pin on the
top is through the hole in audio cap
Step 12 (Vibrator)
Mount the vibrator assembly with the two
connectors facing upwards.