C62 Level 2 Service Manual
Copyright © Siemens Pte Ltd. C62 Level 2 manual V1.1
All Rights Reserved
ICM MP CCQ SLI RHQ 45 of 47 Internal Use Only
Final Inspection:
The final inspection contains:
1) A 100% network test (location update, and set up call).
2) A random sample check of:
- data reset (if required)
- optical appearance
- complete function
3) Check if PIN-Code is activated (delete the PIN-Code if necessary).
Basis is the international standard of DIN ISO 2859.
Use Normal Sample Plan Level II and the Quality Border 0,4 for LSO.
Remark: All sample checks must be documented.