Shared device in the user program
The shared device has no special role in the user program. The submodules assigned to the
station are addressed as usual using their addresses, while the other submodules are not given
an address.
3.4.3 Shared device in di󹪜erent STEP 7 projects
Introduction
The example below describes the con󹪝guration of a shared device in di󹪜erent projects. Two IO
controllers share the submodules of an IO device in the example.
To use the shared device function, steps are required in the con󹪝guration tool as well as in the
hardware con󹪝guration in the con󹪝guration tool.
In the example below, the con󹪝guration of a shared device is described based on the PROFINET
IO device ET 200SP HA (IM 155-6 PN HA) on a SIMATIC CPU 410-5H as IO controller.
Preparation
1. Create a project with the name "Shared-Device-1" in the con󹪝guration tool.
2. Add a station (SIMATIC 410-5H) with the name "CPU1".
3. Open the station in the hardware con󹪝guration in the con󹪝guration tool and con󹪝gure the
CPU with PROFINET interface (a SIMATIC S7 410-5H in the described case).
4. Assign parameters to the PROFINET interface of the station created.
5. Save and compile the station and close the project.
6. Create another project with the name "Shared-Device-2" in the con󹪝guration tool.
7. Add a station (e.g. SIMATIC S7 417) with the name "CPU2".
8. Repeat steps 3 to 5.
Creating a shared device
1. Open the project "Shared-Device-1".
2. Open the station of the IO controller "CPU1" in the hardware con󹪝guration in the
con󹪝guration tool.
3. Con󹪝gure a PROFINET IO device ET 200SP HA (IM 155-6 PN HA) with its own I/O modules.
4. Write down the exact con󹪝guration of the IO device ET 200SP HA created this way.
5. Save and compile the hardware con󹪝guration and close the hardware con󹪝guration in the
con󹪝guration tool and the project.
6. Open the other previously created project "Shared-Device-2".
7. Open the station of the IO controller "CPU2" in the hardware con󹪝guration in the
con󹪝guration tool.