Parameter data record
A.1 Parameter assignment and structure of the parameter data record
Technology Module TM Pulse 2x24V (6ES7138‑6DB00‑0BB1)
158 Manual, 05/2019, A5E35061186-AB
Byte
channel
0/1
Minimum pulse duration:
UDINT: Value range in μs: 0 to 85000000
D
H
Period duration:
UDINT: Value range in μs: 10 to 85000000
D
H
On delay:
UDINT: Value range in μs: 0 to 85000000
D
H
Incline of dithering ramp down:
INT: Value range in ms: 0 to 30000
D
H
Incline of dithering ramp up:
INT: Value range in ms: 0 to 30000
D
H
Dithering amplitude:
UDINT: Value range in ‰: 0 to 500
D
or 0 to 1F4
H
Dithering period duration:
UDINT: Value range in μs: 2000 to 100000
D
H
Reference value current:
Two-channel operation: INT: Value range in mA: 0 to 2000
D
or 0 to 7D0
H
One-channel operation: INT: Value range in mA: 0 to 4000
D
H
Dead band width:
INT: Value range in μA: 0 to 65535
D
H
Manipulated value high limit:
INT: Value range in μA: 1 to 27648
D
H
Manipulated value low limit:
INT: Value range in μA: 0 to 27647
D
H
Proportional gain:
REAL: Floating-point number
Integration time:
REAL: Floating-point number in s
Derivative action time:
REAL: Floating-point number in s
Delay time of derivative action:
REAL: Floating-point number in s
You enable the respective parameter by setting the associated bit to 1.
2
Reserved bits must be set to 0.