EasyManua.ls Logo

Siemens et 200sp - Page 164

Siemens et 200sp
173 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Parameter data record
A.1 Parameter assignment and structure of the parameter data record
Technology Module TM Pulse 2x24V (6ES7138‑6DB00‑0BB1)
Manual, 05/2019, A5E35061186-AB
163
Table A- 5 Parameter data record 128 in the "Frequency output" mode
Bit →
7
6
5
4
3
2
1
0
Byte
channel
0/1
0...3
Header
0
Major Version = 0
Minor Version = 1
1
Length of parameter data per channel = 52
2
Reserved
2
3
4...55
Channel 0
56...107
Channel 1
4/56
Reserved
2
High-speed
output
(0.1 A)
1
Operating mode:
0000
B
: Pulse output
0001
B
: Pulse width modulation PWM
0010
B
: Pulse train
0011
B
: On/Off delay
0100
B
: Frequency output
0101
B
: PWM with DC motor
0101 to 1111
B
: Invalid
5/57
Reserved
2
Group diag-
nostics
1
Reaction to CPU STOP:
00
B
: Output substitute value
01
B
: Reserved
10
B
: Continue operation
11
B
: Reserved
6/58
Reserved
2
Input delay:
Function DI:
0000
B
: None
00
B
: Input
0001
B
: 0.05 ms
01
B
: HW enable
0010
B
: 0.1 ms
10 to 11
B
: Invalid
0011
B
: 0.4 ms
0100
B
: 0.8 ms
0101
B
: 1.6 ms
0110
B
: 3.2 ms
0111
B
: 12.8 ms
1000
B
: 20 ms
1001 to 1111
B
: Invalid
7/59
Reserved
2
Output format:
Diagnostics
DQB
1
Diagnostics
DQA
1
Substitute
value for
DQB
Substitute
value for DQA
00
B
: Invalid
01
B
: 1 Hz
10 to 11
B
: Invalid

Table of Contents

Other manuals for Siemens et 200sp

Related product manuals