Siemens G130 - p9911[0...6] Insert drive object; Drv_obj insert; p9912[0...1] Delete drive object; Drv_obj delete

Siemens G130
1976 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
SINAMICS G130/G150
List Manual (LH2), 07/2016, A5E03263479A
1017
2 Parameters
2.2 List of parameters
Description: New drive objects can be created using this parameter.
Index 0:
The values 2 ... 62 are permissible.
Index 1:
Number of the drive object type (e.g. 11 for type SERVO).
Index 2, 4, 5, 6:
Function modules defined for the drive object.
Index 3:
= 0: Ready.
= 1: Reset (only indices 0 ... 3).
= 2: Reset all (indices 0 ... 3 and flagged entries).
= 3: Check and flag for insertion.
Index: [0] = Drive object number
[1] = Drive object type
[2] = Drive object function module
[3] = Reset or check and flag for insertion
[4] = Drive object function module expansion 1
[5] = Drive object function module expansion 2
[6] = Drive object function module expansion 3
Note: Only for internal Siemens use.
The parameter is not displayed for the STARTER commissioning software.
Description: Drive objects can be deleted using this parameter.
Index 0:
The values 2 ... 62 are permissible.
Index 1:
= 0: Ready.
= 1: Reset (only indices 0 and 1)
= 2: Reset all (indices 0 and 1 and flagged entries).
= 3: Check and flag for deletion.
= 30: Check and flag for deletion. Keep target topology.
Index: [0] = Drive object number
[1] = Reset or check and flag for deletion
Note: Only for internal Siemens use.
The parameter is not displayed for the STARTER commissioning software.
p9911[0...6] Insert drive object / Drv_obj insert
CU_G130_PN,
CU_G150_PN,
CU_G130_DP,
CU_G150_DP
Can be changed: C1(1) Calculated: - Access level: 3
Data type: Unsigned32 Dyn. index: - Func. diagram: -
P-Group: All groups Unit group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 0
Min Max Factory setting
0 4294967295 0
p9912[0...1] Delete drive object / Drv_obj delete
CU_G130_PN,
CU_G150_PN,
CU_G130_DP,
CU_G150_DP
Can be changed: C1(3) Calculated: - Access level: 3
Data type: Unsigned16 Dyn. index: - Func. diagram: -
P-Group: All groups Unit group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 0
Min Max Factory setting
0 62 0