EasyManua.ls Logo

Siemens G130 - Fig. 3-96 2840 - SI Motion drive-integrated control signals; status signals

Siemens G130
1976 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
SINAMICS G130/G150
List Manual (LH2), 07/2016, A5E03263479A
1207
3 Function diagrams
3.11 Safety Integrated Extended Functions
Fig. 3-96 2840 – SI Motion drive-integrated control signals / status signals
- 2840 -
Function diagram
87654321
fp_2840_54_eng.vsd
DO: SERVO, VECTOR
S120/S150/G130/G150
01.04.16 V04.08.00
SI Extended Functions - SI Motion drive-integrated control signals/status signals
p9500 (12.00 ms)
r9722
SI Mtn integ stat
1
7
10
1 = De-select STO
Meaning
1/0 = Acknowledgment
1 = Select SLS bit 0
1 = Select SLS bit 1
0
Bit No.
SI Motion drive-integrated control signals
1
2
1 = STO or safe pulse cancellation active
Meaning
1 = SS1 active
1 = SS2 active
0
Bit No.
4 1 = De-select SLS
1 = De-select SOS
2
3 1 = SOS active
4 1 = SLS active
1 = De-select SS1
1 = De-select SS2
3
9
Active SLS stage bit 110
r9720
SI Mtn integ STW
1 = SSM (speed below limit value)15
11 1 = SOS selected
9 Active SLS stage bit 0
7 1 = Internal event no
1 = SLP active61 = De-select SLP6
13
1 = De-select SDI positive
1 = De-select SDI negative
12 1 = SDI pos active
13 1 = SDI neg active
19 1 = Select SLP position range
SLP active position area19
1 = Safely referenced23
1 = SLP limit upper maintained30
1 = SLP limit lower maintained31
1 = SP valid22
0 = SLS1
1 = SLS2
2 = SLS3
3 = SLS4
0 = SLS1
1 = SLS2
<3>
<1> Only at drive of the Extended Functions via PROFIsafe.
<2> Only at drive of the Extended Functions via TM54F or onboard interface for CU310-2.
<3> S_ZSW1.11 or S_ZSW2.29 depending on the telegram number selected in p9611/p9811 when
actuating the Extended Functions via PROFIsafe.
Reserved
...
0 = SLP1
1 = SLP2
Reserved
...
Reserved
...
Reserved
...
...
Reserved
...
Reserved
...
Reserved
...
Reserved
...
12
Reserved
...
SI Motion drive-integrated status signals
28 1 = De-select SS2E
Reserviert
...
1 = SS2E active28
Reserved
Reserved
...
<1> [2858.6]
<2> [2905.6]
<1> [2858.6]
<2> [2905.6]
<1> [2858.6]
<2> [2905.6]
<1> [2858.6]
<2> [2905.6]
<1> [2858.6]
<2> [2905.6]
<1> [2858.6]
<2> [2905.6]
<1> [2858.6]
<2> [2905.6]
<1> [2858.6]
<2> [2905.6]
<1> [2858.6]
<2> [2905.6]
<1> [2858.6]
<2> [2905.6]
<1> [2858.6]
<2> [2905.6]
<1> [2858.6]
<2> [2905.6]
<1> [2858.6]
<2> [2905.6]
<1> [2858.6]
<2> [2905.6]
<1> [2858.6]
<2> [2905.6]
<1> [2858.6]
<2> [2905.6]
<1> [2858.6]
<1> [2858.6]
<2> [2905.6]
<1> [2858.6]
<2> [2905.6]
<1> [2858.3]
<2> [2905.3]
<1> [2858.3]
<2> [2905.3]
<1> [2858.3]
<2> [2905.3]
<1> [2858.3]
<2> [2905.3]
<1> [2858.3]
<2> [2905.3]
<1> [2858.3]
<2> [2905.3]
<1> [2858.3]
<2> [2905.3]
<1> [2858.3]
<2> [2905.3]
<1> [2858.3]
<2> [2905.3]
<1> [2858.3]
<2> [2905.3]
<1> [2858.3]
<2> [2905.3]
<1> [2858.3]
<2> [2905.3]
<1> [2858.3]

Table of Contents

Related product manuals