Siemens G130 - r0384[0...n] Motor rotor time constant; damping time constant d axis; Mot T_rotor;T_Dd; r0385[0...n] Motor damping time constant q axis; Mot L_damping q; r0386[0...n] Motor stator leakage time constant; Mot T_stator leak; r0387[0...n] Motor stator leakage time constant q axis; Mot T_Sleak;T_Sq

Siemens G130
1976 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
SINAMICS G130/G150
List Manual (LH2), 07/2016, A5E03263479A
157
2 Parameters
2.2 List of parameters
Description: Displays the rotor time constant.
For separately excited synchronous motors:
Displays the damping time constant to the rotor direction (d axis).
Note: The parameter is not used for synchronous motors.
The value is calculated from the total of the inductances on the rotor side (p0358, p0360) divided by the
rotor/damping resistance (p0354). The temperature adaptation of the rotor resistance for induction motors is not
taken into account.
Description: Displays the damping time constant of a separately excited synchronous motor quadrature to the rotor direction (q
axis).
Note: The value is calculated from the total of the inductances on the damping side (p0359, p0361) divided by the damping
resistance (p0355).
Description: Displays the stator leakage time constant.
Note: The value is calculated from the total of all leakage inductances (p0233*, p0353, p0356, p0358) divided by the total of
all motor resistances (p0350, p0352, p0354). The temperature adaptation of the resistances is not taken into
account.
* only applies for VECTOR (r0107).
Description: Displays the stator leakage time constant quadrature to the rotor direction (q axis).
Note: The value is calculated from the total of all leakage inductances (p0233, p0356, p0359) divided by the total of all
motor resistances (p0350, p0352, p0355).
The temperature adaptation of the resistances is not taken into account.
r0384[0...n] Motor rotor time constant / damping time constant d axis / Mot T_rotor/T_Dd
VECTOR_G Can be changed: - Calculated: - Access level: 4
Data type: FloatingPoint32 Dyn. index: MDS, p0130 Func. diagram: 6722
P-Group: Motor Unit group: - Unit selection: -
Not for motor type: PMSM, REL, RESM Scaling: - Expert list: 1
Min Max Factory setting
- [ms] - [ms] - [ms]
r0385[0...n] Motor damping time constant q axis / Mot L_damping q
VECTOR_G Can be changed: - Calculated: - Access level: 4
Data type: FloatingPoint32 Dyn. index: MDS, p0130 Func. diagram: -
P-Group: Motor Unit group: - Unit selection: -
Not for motor type: ASM, PMSM, REL,
RESM
Scaling: - Expert list: 1
Min Max Factory setting
- [ms] - [ms] - [ms]
r0386[0...n] Motor stator leakage time constant / Mot T_stator leak
VECTOR_G Can be changed: - Calculated: - Access level: 4
Data type: FloatingPoint32 Dyn. index: MDS, p0130 Func. diagram: -
P-Group: Motor Unit group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting
- [ms] - [ms] - [ms]
r0387[0...n] Motor stator leakage time constant q axis / Mot T_Sleak /T_Sq
VECTOR_G Can be changed: - Calculated: - Access level: 4
Data type: FloatingPoint32 Dyn. index: MDS, p0130 Func. diagram: -
P-Group: Motor Unit group: - Unit selection: -
Not for motor type: ASM, SESM, REL Scaling: - Expert list: 1
Min Max Factory setting
- [ms] - [ms] - [ms]