2 Parameters
2.2 List of parameters
SINAMICS G130/G150
200 List Manual (LH2), 07/2016, A5E03263479A
Description: Displays the bit number for the safe most significant bit (MSB) of the Gx_XIST1 coarse position.
Note: MSB: Most Significant Bit
Description: Displays the position difference before the measuring gear between switching off and switching on.
Index: [0] = Encoder 1
[1] = Encoder 2
[2] = Encoder 3
Dependency: Refer to: F31501, F32501, F33501
Note: The increments are displayed in the format the same as r0483. The position difference should be read in encoder
increments.
Description: Displays the position difference before the measuring gear between switching off and switching on.
Dependency: Refer to: F31501, F32501, F33501
Note: The increments are displayed in the format the same as r0483. The position difference should be read in encoder
increments.
Description: Display and connector output for the encoder actual position value Gn_XIST1 according to PROFIdrive for
diagnostics.
In contrast to r0482, the value is updated in each DRIVE-CLiQ basic clock cycle and displayed with sign.
Index: [0] = Encoder 1
[1] = Encoder 2
[2] = Encoder 3
r0475 Gx_XIST1 coarse position safe most significant bit / Gx_XIST1 safe MSB
ENC Can be changed: - Calculated: - Access level: 3
Data type: Unsigned16 Dyn. index: - Func. diagram: -
P-Group: Encoder Unit group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting
- - -
r0477[0...2] CO: Measuring gear position difference / Meas gear pos diff
VECTOR_G Can be changed: - Calculated: - Access level: 1
Data type: Integer32 Dyn. index: - Func. diagram: -
P-Group: Encoder Unit group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting
- - -
r0477 CO: Measuring gear position difference / Meas gear pos diff
ENC Can be changed: - Calculated: - Access level: 1
Data type: Integer32 Dyn. index: - Func. diagram: -
P-Group: Encoder Unit group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting
- - -
r0479[0...2] CO: Diagnostics encoder position actual value Gn_XIST1 / Diag Gn_XIST1
VECTOR_G Can be changed: - Calculated: - Access level: 3
Data type: Integer32 Dyn. index: - Func. diagram: 4704
P-Group: Encoder Unit group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting
- - -