Siemens G130 - p0652[0...n] Motor stator resistance scaling; Mot R_stator scal; p0653[0...n] Motor stator leakage inductance scaling; Mot L_S_leak scal; p0655[0...n] Motor magnetizing inductance d axis saturated scaling; Mot L_m d sat scal; p0656[0...n] Motor magnetizing inductance q axis saturated scaling; Mot L_m q sat scal

Siemens G130
1976 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
SINAMICS G130/G150
List Manual (LH2), 07/2016, A5E03263479A
247
2 Parameters
2.2 List of parameters
Description: Sets the factor to evaluate the stator resistance.
Dependency: Refer to: p0350, r0370
Description: Sets the factor to evaluate the stator leakage induction.
Dependency: Refer to: p0356, r0377
Description: Factor to evaluate the magnetizing inductance in the direction of the rotor axis (d axis).
Dependency: Refer to: p0360, r0382
Description: Factor to evaluate the magnetizing inductance quadrature to the rotor axis (q axis).
Dependency: Refer to: p0361, r0383
Description: Factor to evaluate the damping inductance in the direction of the rotor axis (d axis).
Dependency: Refer to: p0358, r0380
p0652[0...n] Motor stator resistance scaling / Mot R_stator scal
VECTOR_G Can be changed: C2(3), U, T Calculated: CALC_MOD_EQU Access level: 4
Data type: FloatingPoint32 Dyn. index: MDS, p0130 Func. diagram: -
P-Group: Motor Unit group: - Unit selection: -
Not for motor type: ASM, PMSM, REL Scaling: - Expert list: 1
Min Max Factory setting
10.0 [%] 300.0 [%] 100.0 [%]
p0653[0...n] Motor stator leakage inductance scaling / Mot L_S_leak scal
VECTOR_G Can be changed: C2(3), U, T Calculated: CALC_MOD_EQU Access level: 4
Data type: FloatingPoint32 Dyn. index: MDS, p0130 Func. diagram: -
P-Group: Motor Unit group: - Unit selection: -
Not for motor type: ASM, PMSM, REL Scaling: - Expert list: 1
Min Max Factory setting
10.0 [%] 300.0 [%] 100.0 [%]
p0655[0...n] Motor magnetizing inductance d axis saturated scaling / Mot L_m d sat scal
VECTOR_G Can be changed: C2(3), U, T Calculated: CALC_MOD_EQU Access level: 4
Data type: FloatingPoint32 Dyn. index: MDS, p0130 Func. diagram: 6727
P-Group: Motor Unit group: - Unit selection: -
Not for motor type: ASM, PMSM, REL Scaling: - Expert list: 1
Min Max Factory setting
10.0 [%] 300.0 [%] 100.0 [%]
p0656[0...n] Motor magnetizing inductance q axis saturated scaling / Mot L_m q sat scal
VECTOR_G Can be changed: C2(3), U, T Calculated: CALC_MOD_EQU Access level: 4
Data type: FloatingPoint32 Dyn. index: MDS, p0130 Func. diagram: 6727
P-Group: Motor Unit group: - Unit selection: -
Not for motor type: ASM, PMSM, REL Scaling: - Expert list: 1
Min Max Factory setting
10.0 [%] 300.0 [%] 100.0 [%]
p0657[0...n] Motor damping inductance d axis scaling / Mot L_damp d scal
VECTOR_G Can be changed: C2(3), U, T Calculated: CALC_MOD_EQU Access level: 4
Data type: FloatingPoint32 Dyn. index: MDS, p0130 Func. diagram: 6727
P-Group: Motor Unit group: - Unit selection: -
Not for motor type: ASM, PMSM, REL Scaling: - Expert list: 1
Min Max Factory setting
10.0 [%] 300.0 [%] 100.0 [%]